• AEE 15 Watt Medical Series

AEE 15 Watt Medical Series

The AEE15W-M series of 15 watt isolated DC-DC converters are designed for demanding instrumentation applications that require supplementary or reinforced insulation to comply with stringent industrial or medical safety standards.
型號 : aee-15-watt-medical series

These converters feature low leakage current and a reinforced insulation system – critical for medical equipment applications – rated for 300 Vac working voltage and 4,200 Vacrms input/output isolation. They comply with the UL/CSA/EN/IEC 60601-1 medical safety standard and are rated for 2X means of patient protection (MOPP).

AEE15W-M series single and dual output converters cover input voltages from 9 to 75 Vdc, with three 2:1 input voltage ranges of 9–18 V, 18–36 V and 36–75 V. Each of the three input voltage categories offers a choice of six models, which produce either single outputs of 5 V, 12 V, 15 V and 24V, or dual outputs of +/-12 V and +/-15V. Rated at 15 watts, the converters have an operating temperature range of -40 to 85˚C, with full power available up to 60˚C. Typical efficiency is 89% maximum.

The converters are fully encapsulated in an industry-standard 2 x1 inch (50.8 x 25.4 mm) low profile plastic case. Standard features include latching overvoltage and overtemperature protection, with hiccup mode overcurrent and short-circuit protection. All AEE15W-M series converters use 285 kHz fixed frequency switching and comply with EN 55022 class A and FCC level A standards for conducted and radiated EMI.
  • Total Max Power:
    15 W
  • Total Max Current:
    3 A
  • Input Voltage:
    9 V to 75 V
  • Output Voltage:
    -15 V to 24 V
  • Outputs:
    Single, Dual
  • Size (L x W x H):
    2.000" x 1.000" x 0.470"
  • Warranty:
    2 years
  • Operating Temperature:
    -40°C to 85°C

  • I/O isolation of 4200 Vac reinforced insulation rated for 300 Vac working voltage
  • Medical safety to UL/CSA/EN/IEC60601-1 4th edition
  • 2 *MOPP rated
  • Wide 2:1 input voltage range
  • Fully regulated output voltage
  • No minimum load requirement
  • Overload/voltage and short circuit protection
  • Low leakage current <5 µA
  • Operating temperature range –40 ˚C to +80 ˚C (with derating)
  • Input filter meets EN55022, ClassA and FCC, Level A
  • Medical EMC Standard meets 4th Edition of EMI EN55011 and EMS EN60601-1-2
  • 2”x 1” plastic package
  • 2 year product warranty

相關產品

AEE 10W - Medical Series

AEE 10W - Medical Series

ASA 6W - Medical Series

ASA 6W - Medical Series

ASA 6W - Medical Series

ASA 6W - Medical Series

AEE 20 Watt Medical Series